Product Introduction
Intelligent instrument calibrator for PT CT error and impedance admittance test.It meets the requirements of JJG313-94 current transformer verification regulation and JJG314-94 voltage transformer verification regulation.
Product Characteristics
1、Intelligent transformer calibrator adopts 320 240 lattice liquid crystal, with large visual range and long life backlight, convenient to use
2、Chinese operation interface, beautiful interface
3、The percentage difference Angle difference is displayed in large font, which is convenient for users to observe
4、The intelligent transformer calibrator produced by our company fully meets the requirements of jjg314-1993 and jjg314-1994, and it can be sampled automatically
5、Automatically judge polarity error, change ratio error
6、The upper computer software has the open function of virtual instrument
7、Completely solve the s-level measurement problem
8、Automatic range switching
9、The perfect combination of advanced and unique circuit and DSP technology can completely remove the problem of the circuit instability
10、power dissipation:<15VA(No micro printer);<25VA(microprinter)
11、Harmonic suppression ratio:>40db
12、boundary dimension(Band dimensions):260×350×150mm3
13、weight:6kg
Parâmetros técnicos
| Ambiente operacional do equipamento | temperature:5℃~40℃ | relative humidity:<80%(25℃) |
| altitude:<2500m | ||
| mains frequency:50Hz±0.5Hz | mains input:220V±5V | |
| faixa de medição | cophase component(%):0.0001~200.0 | distinguishability:0.0001 |
| orthogonal component(part):0.001~700.0 | distinguishability:0.001 | |
| impedance(Ω):0.0001~20.0 | distinguishability:0.0001 | |
| admittance(ms):0.0001~20.0 | distinguishability:0.0001 | |
| erro intrínseco | componente cofase | ΔX=±(X×2%+Y×2%)±Dx(Level 1 is optional) |
| componente ortogonal | ΔY=±(X×2%+Y×2%)±Dy(Level 1 is optional) | |
| "X"、"Y"——Display value of instrument | ||
| "Dx,Dy"——Display value of instrument | ||
| Dx=2,Dy=5 | ||
| indicador de discagem | PETS2 (Nível 1 é opcional) | |
| área de trabalho | eletricidade | (1%~149%)In (In =5A) |
| (5%~149%)In (In =1A) | ||
| tensão | (5%~149%)Un (Un =100V,150V,100V/) | |
| (5%~149%)Un (Un =100V/3) | ||
| carga de trabalho | eletricidade | TO to TX<0.12Ω cosΦ=1 |
| tensão | a to x<0.25VA (100V) | |
| Indicação de erro de polaridade | Quando a corrente de operação (tensão) atingir mais de 5% da corrente nominal (tensão) e o erro exceder 180%, deverá haver indicação de polaridade. | |
| Observação: se for superior a 10% da corrente (tensão) nominal de operação, ainda não há indicação de polaridade adequada, indicando falha. Por favor, não aumente a corrente (tensão) para evitar queimar o instrumento. | ||
| Indicação de erro de proporção variável | Quando a corrente operacional (tensão) atinge mais de 5% da corrente nominal (tensão) e o erro excede 30%, mas é inferior a 180%, deve ser dada a indicação de erro de relação variável. | |
| Teste de isolamento e tensão e instruções | terminalTX( | |
| The power socket can withstand the housing1.5kV,1minwithstand voltage | ||