qiao@hvtest.cc15871365102
  • How to calculate the capacity of series resonance

    The series resonance under Wuhan UHV can help many power workers conduct various power tests more conveniently.


    4


    The capacity calculation of series resonance mainly involves parameters such as inductance, capacitance, and resonant frequency in the circuit. The following is a clear and detailed calculation process, taking into account the relevant numbers and information in the article:

    1、 Basic formula

    In a series resonant circuit, the relationship between the resonant frequency f, inductance L, and capacitance C is given by the following formula:

    [ f = \frac{1}{2\pi \sqrt{LC}} ]

    Among them, f represents the resonant frequency, L represents the inductance value, C represents the capacitance value, and π is the pi.

    2、 Calculate capacitance value

    If the inductance value L and resonant frequency f are known, the required capacitance value C can be deduced by the above formula:

    [ C = \frac{1}{4\pi2 f2 L} ]

    This formula is used to calculate the capacitance value required to achieve a resonant state at a specific resonant frequency.

    3、 Calculate resonant reactance

    In a series resonant circuit, the impedances of the inductor and capacitor cancel each other out during resonance, but the respective reactances of the inductor and capacitor are usually also considered. The reactance XL of an inductor can be calculated using the following formula:

    [ XL = 2\pi fL ]

    The reactance XC of a capacitor is theoretically infinite at resonance (because the impedances of the capacitor and inductor cancel each other out), but in a non resonant state, its reactance can be calculated using the following formula:

    [ XC = \frac{1}{2\pi fC} ]

    4、 Capacity selection of series resonant circuit

    In practical applications, the capacity selection of a series resonant circuit is usually related to the specific requirements of the experiment or application. For example, in the voltage withstand test of power cables, the required device capacity is determined based on the capacitance of the cable and the test voltage. The maximum capacity P of the device can be estimated by the following formula:

    [ P = UI \times 1.25 ]

    Among them, U is the test voltage, and I is the test current. The test current I can be calculated by the capacitance C, resonant frequency f, and test voltage U of the cable. The specific formula may vary depending on the test standard, but the general form may be similar to:

    [ I = 2\pi fCU \times 10^{-3} ]

    (Note: The formulas here are exemplary and should be determined based on specific standards or equipment manuals in actual use.)

    5、 Summary

    The capacity calculation of series resonance involves multiple parameters, including inductance L, capacitance C, resonance frequency f, and test voltage U. By using basic formulas, the required capacitance value at a specific resonant frequency can be calculated, and the capacity of the entire resonant circuit can be determined based on the specific requirements of the experiment or application. In practical operation, it is also necessary to consider the reactance of inductance and capacitance, the influence of resistance, and safety factors.

    Você pode gostar também

    • Tem alguma pergunta!

      NÃO HESITE EM ENTRAR EM CONTATO CONOSCO A QUALQUER MOMENTO
      Contate-nos
    • Visite-Nos

      Edifício 6, Parque Industrial Óptico-Mecânico Optics Valley, 84 Gaoxin 5 Road,
      Zona de Desenvolvimento de Nova Tecnologia de East Lake, cidade de Wuhan, província de Hubei, China

    • Envia-nos um email

      qiao@hvtest.cc

    • Ligue para nós

      +86-15871365102