  • Kit de teste de gerador de alta tensão DC ZGF 200 ~ 400kV DC Hipot

    O testador DC Hipot tipo split da série ZGF 200kV 300kV 400kV é composto principalmente por host principal de controle, cilindro de duplicação de tensão, anel Corona, etc. e pára-raios de óxido de zinco

    Detalhes do produto do kit de teste de gerador de alta tensão DC ZGF 200 ~ 400kV DC Hipot


    ZGF DC Hipot Tester

    Product Introduction

    The ZGF DC Hipot Tester is a specialized high-voltage generating equipment designed for on-site testing in the power equipment field. It features reliable protection functions, including overvoltage, overcurrent, and zero-closing protection, and provides accurate 0.75 times output voltage indication for precise measurement and control.


    Technical characteristics and advantages of DC high-voltage generator

    Stable output: using high-frequency voltage doubling circuit or intermediate frequency inverter technology, with small voltage fluctuations and high testing accuracy.

    Protection function: Equipped with overvoltage, overcurrent, zero start, grounding protection, etc., to ensure safe operation.

    Portability and Integration: The miniaturized design facilitates on-site use, and some models integrate control, measurement, and protection functions into one.


    DC Hipot Test Kit 2
    DC Hipot Test Kit 3


    Technical Parameters

    Especificações200/2200/3200/5300/2300/3300/5400/2400/3400/5
    Rated voltage(kV)200200200300300300400400400
    Rated current(mA)235235235
    rated power(W)4006001000600900150080012002000
    Control box quality(kg)5.56.06.510.510.510.510.510.510.8
    Pressure cylinder quality(kg)8.799242424.533.533.533.5
    Double cylinder height(mm)970970970125012501250165016501650
    Precisão de tensão±(1,0%Leitura + 2 palavras)
    Precisão atual±(1,0%Leitura + 2 palavras)
    Coeficiente de ondulação≤0.5%
    Estabilidade de tensãoQuando a tensão da fonte de alimentação muda em ±10%≤1%
    Capacidade de sobrecargaA tensão sem carga pode exceder 10% da tensão nominal por 10 minutos
    A corrente máxima de carga é 1,25 vezes a corrente nominal
    fonte de energiaComunicação monofásica 50Hz 220V±10%
    Maneira de trabalharUso intermitente: carga nominal 30 minutos
    1,1 vezes o uso de tensão nominal: 10 minutos
    Maneira de trabalhartemperature:-10℃~+40℃
    Relative humidity: no more than 85% at room temperature of 25 °C (no condensation)
    Altitude: abaixo de 1500 metros
    Com capacidade de carga capacitivaO produto testado tem capacidade ilimitada
    Carregado com 1,5 vezes a corrente nominal
    Características estruturaisElectrical insulation doubler
    Isolamento de ar, sem vazamento
    Recursos da caixa operacionalBotão de um toque 0,75UDC1mA de alta precisão (precisão ≤1,0%), adequado para teste de pára-raios de óxido de zinco
    Proteção contra sobretensão usando interruptor digital, em resumo
    Chassi portátil, mais conveniente no local


    Âmbito de aplicação

    1. Conductivity current test of valve type lightning arrester.

    2. DC withstand voltage test and leakage current measurement of power transformers.

    3. Teste de tensão suportável DC e medição de corrente de fuga de cabos de alta tensão (35-500kV e abaixo).

    4. U1mA DC reference voltage test and 0.75U1mA leakage current test for zinc oxide lightning arrester.


    DC Hipot Test Kit 5
    DC Hipot Test KitDC Hipot Test Kit 4


    Core application scenarios

    1、 Insulation performance testing of power equipment

    1. Voltage withstand test of high-voltage electrical equipment

    Transformer: Test the insulation strength of the winding to ground and between layers to ensure that there is no risk of breakdown during long-term operation at rated voltage.

    Switchgear: Detect the insulation reliability of components such as contacts and insulators under high voltage, and prevent partial discharge or breakdown accidents.

    Transformer: Verify the electrical performance of insulation materials in high voltage environments, ensuring measurement accuracy and equipment safety.

    2. DC reference voltage test for lightning arrester. Measure the leakage current of lightning arrester under DC voltage, evaluate its nonlinear resistance characteristics, and ensure the normal overvoltage protection function.

    2、 Cable and accessory testing

    1. DC withstand voltage test for power cables. Detect the voltage resistance of the main insulation of the cable (such as cross-linked polyethylene) under high DC voltage, and discover manufacturing defects or aging damage.

    2. Performance verification of cable accessories. Test the insulation performance of cable terminals and intermediate joints to ensure that there is no partial discharge or breakdown at the joint location under high voltage.

    3、 Testing of Insulation Materials and Components

    1. Inspection of high-voltage components such as insulators and bushings. Apply high DC voltage, measure leakage current, evaluate surface hydrophobicity, pollution tolerance, and internal defects of insulators.

    2. Dielectric loss test of capacitors. By measuring the capacitance and dielectric loss tangent (tan δ) under high DC voltage, the degree of dielectric aging of capacitors can be determined.

    4、 Special industry applications

    1. Detection of electrified railway contact network. Test the voltage resistance performance of components such as contact line insulators and section insulators to ensure the safety of train power supply.

    2. Testing of new energy equipment. Used for insulation performance verification of photovoltaic inverters, wind power converters and other equipment to ensure their reliability in complex power grid environments.


    Frequently Asked Questions

    Q: What is the difference between a DC high-voltage generator and an AC high-voltage generator?
    A: A DC high-voltage generator outputs a stable, constant direct current and is mainly used for DC withstand voltage tests. An AC high-voltage generator, on the other hand, outputs alternating current and is mainly used for AC withstand voltage tests, with a different approach to assessing insulation performance.
    Q: What safety precautions should be taken when using a DC high-voltage generator?
    A: Ensure that the equipment is properly grounded, and that operators wear insulating shoes and insulating gloves and stay well away from the high-voltage output terminals. During testing, a supervisor should be present, and all personnel should be familiar with emergency response procedures.
    Q: How can I judge the quality of a DC high-voltage generator?
    A: It can be evaluated in terms of output voltage stability, ripple factor, overload capacity, insulation performance, and the sensitivity of its protection functions.
    Q: What materials can be tested with a DC high-voltage generator?
    A: It can be used for various insulating materials, such as plastics, rubber, ceramic parts, oil‑impregnated paper, etc., as well as for DC insulation performance testing on high‑voltage electrical equipment like power cables, transformers, and instrument transformers.







    Você pode gostar também

    • Tem alguma pergunta!

      NÃO HESITE EM ENTRAR EM CONTATO CONOSCO A QUALQUER MOMENTO
      Contate-nos
    • Visite-Nos

      Edifício 6, Parque Industrial Óptico-Mecânico Optics Valley, 84 Gaoxin 5 Road,
      Zona de Desenvolvimento de Nova Tecnologia de East Lake, cidade de Wuhan, província de Hubei, China

    • Envia-nos um email

      qiao@hvtest.cc

    • Ligue para nós

      +86-15871365102