Product Introduction
Intelligent Battery Charge and Discharge Tester – Utilizing proprietary technology, it enables offline constant-current discharge with real-time current regulation and auto-stop (triggered by voltage, time, or capacity limits), while logging full-process data. Equipped with wireless cell voltage monitoring, a user-friendly interface, and data export capabilities, it ensures safe and efficient testing with multi-layer protection.
Product Features
1、Wide Voltage Range (10-600V) – Supports multiple battery types with continuously adjustable voltage for flexible testing.
2、Precision Constant-Current Discharge – Adjustable current ensures accurate battery capacity measurement.
3、Wireless Cell Monitoring – Each module tracks up to 12 cells simultaneously for real-time voltage analysis.
4、PC Analysis Software – Enables data review and remote-controlled discharge (Chinese UI supported).
5、High-Capacity Data Storage – Built-in 2GB memory and USB interface for easy data export.
6、Dual-CPU Safety Design – Enhances test reliability, accuracy, and protection during operation.
Technical Parameters
Applicable battery | 24V、48V、72V、96V、110V、220V、240V、380V、480V | |||
Working mode | can be used alone, can be used simultaneously, can be remote control and status monitoring | |||
Discharge voltage | DC 10V~300V | DC 10V~600V | ||
Discharge current | 10~19V:0~50A; 19~180V:0~100A; 180~300V:0~50A; | 10~19V:0~80A; 19~180V:0~120A; 180~300V:0~80A; | 10~19V:80A; 19~180V:120A; 180~300V:80A; 300~600V:50A; | 10~19V:150A; 19~180V:300A; 180~300V:150A; 300~600V:60A; |
Accuracy of current | 1% | |||
Voltage accuracy | 0.5% | |||
Monomer voltage accuracy | 0.2% | |||
Monomer voltage | 0.500V~16.00V(resolution 1mv) | |||
Charge discharge time | 0 ~ 99 hours and 59 minutes | |||
Power supply | AC:220V | |||
Cooling way | forced air cooling | |||
Packaging | aluminum alloy pull box |
Work Environment
Heat dissipation | forced air cooling |
Temperature | working range: -5 ~ 50℃ storage temperature: -40 ~ 70℃ |
Humidity | relative to humidity0 ~ 90% (40±2℃) |
Altitude | rated altitude: 4000 m |
Noise | ﹤60dB |
Working Power Supply
Voltage | single-phase three-wire system: 220V AC (- 20% ~ +30%), frequency :45 ~ 65Hz |
Withstand voltage test | input - housing: 2200V DC 1min |
input-output: 2200V DC 1min | |
output - housing: 700V DC 1min | |
Security | meet EN610950 |
Wiring
AC input | Gb socket, suitable for 1 ~ 1.5mm2cable |
DC output | instrument 25 mm2Cable quick connect plug (red positive black negative) |