  • Transformador de teste inflável sem descarga parcial da série YDQW

    Gás SF6 com alta capacidade de isolamento como meio isolante. Baixa capacidade de descarga local, capacidade de descarga local com tensão nominal ≤ 5PC. Acabamento de alta qualidade, aparência elegante e fácil manuseio.

    Product Details of YDQW Series Inflatable No Partial Discharge Test Transformer

    b5b8fc71abe60022cf61860187f435cd


    Product parameters:

    Used for manufacturers of electrical appliances, cables, motors, transformers, mutual inductors, insulation materials, and related high-voltage components, as well as high-voltage testing laboratories in power, scientific research, and universities, to conduct partial discharge and power frequency withstand voltage tests on their products.

    aa73a372533993b0e04275fffd83e738


    Technical parameters:

    Modelo

    Matching KVA with YDQW

    YDQW-2

    1.5

    YDQW -3

    3

    YDQW -5

    5

    YDQW -10

    10

    YDQW -20

    20

    YDQW -30

    30

    YDQW -50

    50

    1. For transformers of various voltage levels, the no-load current is 4-9% and the impedance voltage is 4-10%.

    2. Control the existing specifications and operating time of the control part.

    Note: Can be matched according to user requirements


    Recurso:

    1. The design concept, material selection, and process flow are all brand new, so not only is it small in size, light in weight, and beautiful in appearance, but all technical indicators have met the requirements of JB3570-98 standard.

    2. Made using a completely new process, the dielectric insulation material used is completely different from other products, resulting in a product with no partial discharge effect.


    working principle:

    The control panel (box) with overcurrent automatic tripping and zero position interlocking device to prevent sudden pressurization of the power input is regulated by an autotransformer to input voltage into a non partial discharge filter isolation filter transformer, and then output from the non partial discharge filter isolation filter transformer

    To test the primary winding of the transformer, according to the principle of electromagnetic induction, the secondary (high voltage) winding can obtain an equal multiple of voltage amplitude - power frequency high voltage - based on the ratio of its turns to the primary winding.










    Você pode gostar também

    • Tem alguma pergunta!

      NÃO HESITE EM ENTRAR EM CONTATO CONOSCO A QUALQUER MOMENTO
      Contate-nos
    • Visite-Nos

      Edifício 6, Parque Industrial Óptico-Mecânico Optics Valley, 84 Gaoxin 5 Road,
      Zona de Desenvolvimento de Nova Tecnologia de East Lake, cidade de Wuhan, província de Hubei, China

    • Envia-nos um email

      qiao@hvtest.cc

    • Ligue para nós

      +86-15871365102