    Gás SF6 com alta capacidade de isolamento como meio isolante. Baixa capacidade de descarga local, capacidade de descarga local com tensão nominal ≤ 5PC. Acabamento de alta qualidade, aparência elegante e fácil manuseio.

    Product Details of YDQW Series Inflatable No Partial Discharge Test Transformer

    Product Introduction:

    Used for manufacturers of electrical appliances, cables, motors, transformers, mutual inductors, insulation materials, and related high-voltage components, as well as high-voltage testing laboratories in power, scientific research, and universities, to conduct partial discharge and power frequency withstand voltage tests on their products.


    Technical parameters:

    Parâmetros

    Value

    Capacidade nominal

    50-1200kVA

    Tensão de entrada

    380 V

    Voltagem de saída

    50-1200kV

    Tempo de execução

    ≤5 minutos

    Precisão de medição

    ≤1.5%

    Partial discharge capacity

    ≤5Pc

    Protection function

    Overcurrent and voltage protection alarm automatically return to zero


    Recurso:

    1. Filled with SF6 gas, which features high insulation strength, as the insulating medium.

    2. Compact and lightweight design with high-quality craftsmanship, attractive appearance, and easy handling.

    3. Benefiting from the arc-extinguishing properties and specialized structural design involving SF6 gas, the unit exhibits low partial discharge levels, measuring ≤5 PC at rated voltage.

    4. The testing process is simple, intuitive, and user-friendly.

    5. Effectively eliminates clutter interference from the power supply.

    6. Integrates automatic control technology, offering a high degree of automation and strong anti-interference capability.

    7. Equipped with a fast-acting electronic protection device, ensuring high reliability.


    Working principle:

    The control panel (box) with overcurrent automatic tripping and zero position interlocking device to prevent sudden pressurization of the power input is regulated by an autotransformer to input voltage into a non partial discharge filter isolation filter transformer, and then output from the non partial discharge filter isolation filter transformer

    To test the primary winding of the transformer, according to the principle of electromagnetic induction, the secondary (high voltage) winding can obtain an equal multiple of voltage amplitude - power frequency high voltage - based on the ratio of its turns to the primary winding.








    Você pode gostar também

    • Tem alguma pergunta!

      NÃO HESITE EM ENTRAR EM CONTATO CONOSCO A QUALQUER MOMENTO
      Contate-nos
    • Visite-Nos

      Edifício 6, Parque Industrial Óptico-Mecânico Optics Valley, 84 Gaoxin 5 Road,
      Zona de Desenvolvimento de Nova Tecnologia de East Lake, cidade de Wuhan, província de Hubei, China

    • Envia-nos um email

      qiao@hvtest.cc

    • Ligue para nós

      +86-15871365102