qiao@hvtest.cc15871365102
  • Testador de resistência CC para transformador de três circuitos UHV-S10A

    O instrumento possui alta capacidade de corrente de saída e seleção automática de corrente, facilitando a operação. Conta com um circuito de proteção completo e altamente confiável. A carcaça de plástico industrial é leve e prática para transporte.

    Product Details of UHV-S10A Three-circuit Transformer DC Resistance Tester


    Product Introduction

    This DC resistance rapid tester is the latest generation product for measuring the DC resistance of transformers, optimized for measuring the DC resistance of three-phase windings in large capacity transformers. Simultaneously test the DC resistance of the three-phase winding of the transformer.


    Parâmetros técnicos

    Testing currentSingle phase:1A 5A 10A 20A
    Three phase:1A 5A 10A
    Measurement scopeSingle phase
    1A 10mΩ ~ 20Ω
    5A 1mΩ ~ 4Ω
    10A 1mΩ ~ 2Ω
    20A 1mΩ ~ 1Ω
    Three phase
    1A 10mΩ ~ 6Ω (each phase)
    5A 1mΩ ~ 1Ω (each phase)
    10A 1mΩ ~ 0.6Ω (each phase)
    Precisão de medição± (0.2%Full span ± 2 words )
    Maximum resolution0,1mΩ
    Data storage capacity150 groups
    Fonte de energiaAC 220V±22V,50Hz±2Hz
    Ambiente de trabalhoAmbient temperature: 0°~40° Relative humidity :≤80%


    Product Features:

    1. Simultaneously test the DC resistance of the three-phase winding of the transformer.

    2. For on load tap changers, there is no need for discharge, and the tap changer can be directly adjusted. The measurement time is one-third of traditional single-phase measurement, which can greatly shorten the working time and labor intensity.

    3. The direct resistance meter adopts a large screen LCD display with a fully Chinese graphical interface, which is clear and intuitive, and the operation is very simple.

    4. And equipped with a panel printer and large capacity non-volatile memory, it can conveniently store and print measurement results.

    5. The test data is stable, fast, and has good repeatability, making it the best choice for on-site measurement of transformer DC resistance.


    Matters needing attention:

    1. When measuring an unloaded voltage regulating transformer, the discharge must be exited before switching the tap changer. The tap changer can only be switched after the discharge indication is complete

    2. It is not allowed to dismantle the wiring during the measurement process.

    3. If the charging progress bar and current display value remain stagnant for a long time, the measured winding resistance may exceed the current measurement range, and the current may not reach the preset value. At this point, you can press the 'Exit' button to return, select the current again, and try again.

    4. When replacing the fuse and accessories, please use the same model as this instrument








    Você pode gostar também

    • Tem alguma pergunta!

      NÃO HESITE EM ENTRAR EM CONTATO CONOSCO A QUALQUER MOMENTO
      Contate-nos
    • Visite-Nos

      Edifício 6, Parque Industrial Óptico-Mecânico Optics Valley, 84 Gaoxin 5 Road,
      Zona de Desenvolvimento de Nova Tecnologia de East Lake, cidade de Wuhan, província de Hubei, China

    • Envia-nos um email

      qiao@hvtest.cc

    • Ligue para nós

      +86-15871365102