  • Medidor de baixa resistência do verificador 20A da resistência do enrolamento da CC do transformador UHV-20A

    O testador de resistência de enrolamento CC para transformadores da série UHV é usado principalmente para testar a resistência do enrolamento de transformadores ou reatores de alta tensão. Possui múltiplas funções de proteção, como proteção contra força contraeletromotriz, proteção contra desconexão, proteção contra falha de energia, alarme de superaquecimento, etc.

    Detalhes do produto do testador de resistência de enrolamento DC do transformador UHV-20A 20A medidor de baixa resistência


    UHV-20A DC Resistance Tester

    Transformer Winding DC Resistance Measurement

    Measuring the DC resistance of transformer windings is an essential test during transformer acceptance, maintenance, and tap-changer adjustments. Traditional methods, such as the bridge method and voltage drop method, are often time-consuming and labor-intensive, particularly for high-power inductive equipment. 

    To overcome these challenges, our company has developed the DC Resistance Rapid Tester. Utilizing advanced power technology, this instrument delivers stable performance, rapid testing, compact size, lightweight design, and user-friendly operation. It achieves high measurement accuracy and excellent data reproducibility, making it the ideal solution for efficient DC resistance testing of transformer windings and other high-power inductive devices.

    4 副本


    características do produto

    1、Compact and Lightweight: Small size and low weight for easy portability.

    2、User-Friendly Operation: Simple and intuitive controls for ease of use.

    3、Efficient and Accurate Testing: High-speed measurement with stable and precise results.

    4、Enhanced Safety Functions: Equipped with automatic discharge and discharge indication, reducing misuse and ensuring safety for both personnel and equipment.


    Transport and Storage
    Transport
    If the instrument needs to be transported, it is recommended to use our packing wooden boxes and cushioning materials to avoid unnecessary damage and losses.
    If do not use wooden box wooden in transit, it is not allowed to stack devices randomly. The allowable maximum packing stacking layer is two layers.
    In transit, the instrument panel should be faced up.
    Armazenar
    The instrument should be placed in a dry, clean, ventilated, non-corrosive gases room. In the absence of wooden packing cases, it is not allowed to stack randomly.
    In storage, the instrument panel should be faced up. And add damp-proof pad at the bottom of the instrument to prevent it from moisture.


    Parâmetros técnicos

    ItemTechnical specifications and parametersRemarks
    Measure current1A, 5A, 10A, 20A/
    Measure Range1A:10mΩ~20Ω/
    5A:1mΩ~4Ω
    10A:1mΩ~2Ω
    20A:1mΩ~1Ω
    Precisão±0.2%(full range)/
    Data Storage255
    MostrarLCDResistance display:4 1/2 bits
    Maximum resolution0,1mΩ/
    Fonte de energiaAC 220V±22V,50Hz±2 HzFuse 5A
    Maximum Power Dissipation300WTest current:10A/hour
    Ambiente de trabalhoTemperature:0℃~40℃/
    Relative Humidity:≤80%RH
    Dimensão200╳400╳280 (mm)/
    Peso6kgIncluding accessories


    Application Scenarios

    Power transformer factory quality inspection — After transformer manufacturing is completed, perform DC resistance measurement on the high-voltage and low-voltage windings of oil-immersed transformers, dry-type transformers, and special transformers. This is used to check winding conductor connection quality, soldering reliability, and three-phase resistance balance. It is a key test item in transformer production inspection.

    Substation installation, commissioning, and acceptance — After equipment installation is completed in newly built or expanded substations, perform on-site DC resistance testing on main transformers, auxiliary transformers, and distribution transformers to verify that winding and lead connections are normal during transportation and installation, ensuring the equipment meets requirements for power transmission and operation.

    On-load tap-changer performance testing — For transformers with voltage regulation capability, perform resistance measurement at different tap positions to analyze the contact condition of the tap changer contacts, and determine whether there are potential fault hazards such as contact oxidation, erosion, or abnormal contact resistance.


    FAQ about Transformer DC Winding Resistance Tester

    What is a transformer DC winding resistance tester, and why is winding resistance testing necessary?

    A transformer DC winding resistance tester is a specialized power testing device used to measure the DC resistance value of transformer windings. It calculates the winding resistance by applying a stable DC current to the winding and measuring the voltage response.Winding resistance testing can effectively evaluate winding conductor connection quality, soldering reliability, tap changer contact condition, and whether the winding has any abnormalities. It is an important testing item in transformer manufacturing, installation, maintenance, and operation and maintenance.


    Does a larger transformer capacity make DC winding resistance testing more difficult?

    Yes. For large power transformers, the winding resistance is relatively low, while the winding inductance is large, requiring a longer stabilization time during testing.High-performance DC winding resistance testers typically employ high-current constant-current output, fast sampling, and automatic discharge technology, which can shorten test time and improve on-site testing efficiency for large transformers.


    Can the transformer DC winding resistance tester be used in conjunction with other power testing equipment?

    Yes. DC winding resistance testing is typically used together with transformer turns ratio testers, insulation resistance testers, dielectric loss testers, partial discharge detection equipment, and other instruments, forming a comprehensive transformer condition testing system.By comprehensively analyzing data from multiple test items, the transformer's insulation condition, winding performance, and operational reliability can be more thoroughly evaluated.









    Você pode gostar também

    • Tem alguma pergunta!

      NÃO HESITE EM ENTRAR EM CONTATO CONOSCO A QUALQUER MOMENTO
      Contate-nos
    • Visite-Nos

      Edifício 6, Parque Industrial Óptico-Mecânico Optics Valley, 84 Gaoxin 5 Road,
      Zona de Desenvolvimento de Nova Tecnologia de East Lake, cidade de Wuhan, província de Hubei, China

    • Envia-nos um email

      qiao@hvtest.cc

    • Ligue para nós

      +86-15871365102